Skip to content

4. The safety chain ​

4.1 Every command through one gate ​

Only control_mux_node publishes /x30/cmd_vel. Navigation (control/nav_cmd_vel) and the operator sources (control/remote/<source>/cmd_vel) publish to it; it forwards one of them, AUTO or REMOTE, after the envelope, the health speed scale (optional) and the protective field, and holds zeros during an e-stop. The follower has its own guard on the same scan, with margins at least the field’s: in normal operation the field never has to act.

4.2 Stops ​

StopPathEffect
Hard emergency stop (robot)Deep Robotics’ hardwarethe joints off: the robot drops
H12 STOPgateway: control/estop_request at once, then control/estop/engagezeros held; a patrol pauses; release by a held STOP, then neutral sticks
NETRA E-stopuplink: the same twoas above
emergency_stop commandthe driver’s service; the e-stop latched toothe robot’s own emergency stop
control/hw_estopa hardware input (optional)engaged while true or silent for hw_estop_timeout_sec
Deep Robotics’ handheldtakes over the robot (manual mode)the stack’s commands no longer reach the legs until the robot is back in its mode

4.3 When something falls silent ​

SilentAfterThen
The handheld (stick)0.3 sthe mux sends one zero; the gateway drops the handheld after 2 s
Navigation0.5 sthe mux sends one zero
The safety scan0.5 sthe field: STALE (AUTO stops, REMOTE creeps); the follower holds
The LiDAR (no cloud)0.5 severy sector BLOCKED
The robot’s pose0.5 sthe follower holds
The mux0.5 sthe driver sends zeros, then stops streaming
The driver1 sthe robot drops the axis by itself
A critical node, the ROS masterwatchdogx30_watchdog.py restarts the host’s launch

4.4 What is not certified ​

The e-stops of the H12 and NETRA, the protective field and the guard are software on a computer without a safety rating. They reduce risk; the hard emergency stop on the robot, Deep Robotics’ handheld and a responsible operator are the protection, and the site’s risk assessment decides where the robot may walk.